Phone/Fax: (812) 493-50-48

En

Water coolers OPV 8 modifications

FUNCTION AND TECHNICAL DATA

The cooler is intended to cool oil, hydraulic systems liquids, fresh and distilled water, as well as sea water in systems of marine power stations; cool auxiliaries and other systems of ships and vessels.

Working (design) pressure of the cooling water, MPa (kg-f/cm²), max

6,4 (64) for OPV 14-3, OPV-17, OPV-47, OPV-135 8,5 (85) for OPV-155

Medium to be cooled

distilled or fresh water

8 modifications (Click on row to compare)
Index Mode Area of the heat-exchange surface, m² Weight, kg Temperature of the medium to be cooled at the cooler inlet, К (ºС) Temperature of the medium to be cooled at the cooler outlet, К (ºС) Hydraulic resistance of the cooling medium, MPa (kg-f/cm²) Temperature of the cooling medium at the cooler inlet, К (ºС) Hydraulic resistance of the cooling medium, MPa (kg-f/cm²) Amount of the medium to be cooled, m³/h Pressure of the medium to be cooled, MPa (kg-f/cm²) Overall dimensions, mm
OPV 14-3 1 13.7 335/445 315(42) 311(38) 0.03(0.3) from - 2 up to + 33 0.035(0.35) 30 0,4(4,0) 565x580x1265
OPV 14-3 2 13.7 335/445 316(43) 310(37) 0.065(0.65) от -2 до +33 0.075(0.75) 50 0,065(0,65) 565x580x1265
OPV-17 1 16.7 430 37.7 35 0.014 (0.14) from - 2 up to + 32 0.023 (0.23) 22.4 0.7(7) 1303x717x718
OPV-17 2 16.7 430 48 42.5 0.02(0.2) from +22 up to +36 0.02(0.2) 28 0.7(7) 1303x717x718
OPV-47 45-50 763 42 38 0.05(0.5) 32 0.06(0.6) 250 1.0(10) 2475x717x842
OPV-135 1 135 2500/3650 40 36 0.08(0.8) 32 0.016 (0.156) 200 1.0(10) 2965x1150x1246
OPV-135 2 135 2500/3650 37.7 25 0.08(0.8) 20 0.003(0.03) 150 1.0(10) 2965x1150x1246
OPV-155 155 3778/4958 from +2 up to +82 - 0.07(0.7) from - 2 up to + 32 0.017 (0.17) 105 1.0(10) 3350x1180x1100
Order

All fields are required

Feedback